The following trainPartSequence has tow references in the UNO topology register. The first one refrences the external topology version used to determine the train running path and calculate the runtimes from 1 February to 31 August 2017 of the train operating days. The second reference points to the external version used for the operating days from 1 September to 31 December 2017. | The following trainPartSequence has tow references in the UNO topology register. The first one refrences the external topology version used to determine the train running path and calculate the runtimes from 1 February to 31 August 2017 of the train operating days. The second reference points to the external version used for the operating days from 1 September to 31 December 2017. | ||
Thus, for the train operating days from 1 February to 31 August 2017 the UNO topology version " | Thus, for the train operating days from 1 February to 31 August 2017 the UNO topology version "183000-01012017" is used. For the operating days from 1 September to 31 Decenber 2017 the UNO version "120000-08012017" is referenced. | ||
<syntaxhighlight lang="xml"> | <syntaxhighlight lang="xml"> | ||
<trainPartSequence sequence="1"> | <trainPartSequence sequence="1"> | ||
<trainPartRef ref="train-part-1" /> | <trainPartRef ref="train-part-1" /> | ||
<topologyReference topologyRegister="UNO" entry=" | <topologyReference topologyRegister="UNO" entry="183000-01012017" startDate="2017-02-01" endDate="2017-08-31" /> | ||
<topologyReference topologyRegister="UNO" entry=" | <topologyReference topologyRegister="UNO" entry="120000-08012017" startDate="2017-09-01" endDate="2017-12-31" /> | ||
</trainPartSequence> | </trainPartSequence> | ||
</syntaxhighlight> | </syntaxhighlight> | ||
}} | }} |
Revision as of 09:57, 30 November 2017
|
|
topologyReference
Scheme description / Schemenbeschreibung
Position of topologyReference in the XML-Tree / Position von topologyReference im XML-Baum
- Parent: <trainPartSequence>
- Children: None
Multiplicity / Anzahl
Semantics / Bedeutung
The topologyReference element (introduced with version 2. 4) can be used to refer the underlying topology, which was used to determine the train running path and calculate the runtimes. Specifying the topology register and an optional time period, the attribute entry is used to refer to the external version / variant within the topology register. This assumes that the reading system also knows the topology register and can interpret the version / variant definition. When specifying multiple topology references, these must have a disjoint time period and, combined together, cover at least the operating days of the train.
Mit dem topologyReference Element kann für einen Zug die zugrundeliegende Topologie, welche für die Ermittlung des Fahrweges und Berechnung der Fahrzeiten verwendet wurde, referenziert werden. Unter Angabe des Topologie-Registers sowie einer optionalen Zeitperiode wird mit dem Attribut entry die Version / Variante innerhalb der externen Topologie referenziert. Dies setzt voraus, dass das lesende System das Topologie-Register ebenfalls kennt und die Version / Variante interpretieren kann. Bei der Angabe mehrerer Referenzen müssen diese einen disjunkten Zeitraum haben sowie in der Kombination mindestens die Betriebstage des Zuges abdecken. (introduced with version 2.4)
Attributes of topologyReference / Attribute von topologyReference
- topologyRegister: A string value for defining the catalogue, index, or directory where the external topology reference comes from or refers to. Attribute register is used to link a topologyReference with the codelist TopologyRegisters.xml. See below for a list of the currently registered catalogues.
- entry: Contains the external key of the referred register.
- startDate: Begin of the validity period for the topology reference.
- endDate: End of validity period for the topology reference.
- xs:anyAttribute: This provides an extension point for non-railML® attributes in a foreign namespace. How to use it?
Syntactic Constraints / Syntaktische Beschränkungen
- topologyRegister xs:string, required: For short-time or internal purposes new string value entries can be used additional to that of railML's XSD. But for official data exchange between two software programs it is _strongly_ recommended that each new 'register' entry has to be 'registered' at the Scheme Coordinator and included into the codelist TopologyRegisters.xml.
- entry: xs:string, required: May be a string or a number depending on the 'register'. This means, some 'register' entries require a pure numeric number and do not allow characters or other signs. This is not forced by railML so far.
- startDate: xs:date, optional
- endDate: xs:date, optional
Best practice & Examples / Empfohlene Anwendung & Beispiele
The following trainPartSequence has tow references in the UNO topology register. The first one refrences the external topology version used to determine the train running path and calculate the runtimes from 1 February to 31 August 2017 of the train operating days. The second reference points to the external version used for the operating days from 1 September to 31 December 2017.
Thus, for the train operating days from 1 February to 31 August 2017 the UNO topology version "183000-01012017" is used. For the operating days from 1 September to 31 Decenber 2017 the UNO version "120000-08012017" is referenced.
<trainPartSequence sequence="1"> <trainPartRef ref="train-part-1" /> <topologyReference topologyRegister="UNO" entry="183000-01012017" startDate="2017-02-01" endDate="2017-08-31" /> <topologyReference topologyRegister="UNO" entry="120000-08012017" startDate="2017-09-01" endDate="2017-12-31" /> </trainPartSequence>
Notes / Anmerkungen
Currently predefined 'register' enumeration entries:
- UNO Central topology database for railway systems (source: Swiss Federal Railways).
Open issues / Offene Punkte/Pendenzen
Not yet described. / Noch nicht beschrieben.