The element <winding> contains the nominal values for each transformer winding.
Das Element <winding> enthält die Bemessungsdaten für die einzelnen Wicklungen des Haupttransformators.
Attributes of winding / Attribute von winding
- assemblyName: This is the type of transformer winding as descriptive name.
- nominalVoltage: This is the nominal voltage of transformer winding at primary side in Volts.
- nominalCurrent: This is the nominal current of transformer winding at primary side in Ampere.
- transformationRatio: This is the transformation ratio of the transformer winding according to the relation of primary/secondary voltage.
- primaryResistance: This is the resistance of primary winding of one transformer in Ohms.
- secondaryResistance: This is the resistance of secondary winding of one transformer in Ohms transformed to primary side.
- primaryLeakageInductance: This is the leakage inductance of primary winding of one transformer in Henry.
- secondaryLeakageInductance: This is the leakage inductance of secondary winding of one transformer in Henry transformed to primary side.
Syntactic Constraints / Syntaktische Beschränkungen
- assemblyName xs:string, mandatory
- nominalVoltage xs:decimal, 1 fraction digit, voltage value measured in Volt, optional
- nominalCurrent xs:decimal, 1 fraction digit, current value measured in Ampere, optional
- transformationRatio xs:decimal, optional
- primaryResistance xs:decimal, 3 fraction digit, electrical resistance value measured in Ohms, optional
- secondaryResistance xs:decimal, 3 fraction digit, electrical resistance value measured in Ohms, optional
- primaryLeakageInductance xs:decimal, 6 fraction digit, electrical inductance value measured in Henry, optional
- secondaryLeakageInductance xs:decimal, 6 fraction digit, electrical inductance value measured in Henry, optional
The element <winding> is optional and can occur several times.