RS:energyStorage

From railML 2 Wiki
Revision as of 13:20, 12 February 2011 by RailML Coord Rollingstock (talk | contribs) (detailed description)
Jump to navigation Jump to search


energyStorage
 


Scheme description / Schemenbeschreibung

Position of energyStorage in the XML-Tree / Position von energyStorage im XML-Baum

Multiplicity / Anzahl

[1..1]

Semantics / Bedeutung

(after version 2.0)

The element <energyStorage> is the container for all data of energy storage device on the vehicle. The main focus is on the electrical characteristics.

Das Element <energyStorage> stellt den Container für alle Daten bezüglich eines Energiespeichers auf dem Fahrzeug zur Verfügung. Dabei liegt das Hauptaugenmerk auf den elektrischen Eigenschaften.

Attributes of energyStorage / Attribute von energyStorage

  • id: Unique identifier which is used to refer to this particular item. This ID is always required for the item. It is inherited as a common feature from the type tElementWithIDAndName.
  • code: A short string for typical, specific abbreviations, used in different systems with the same understanding.
  • name: A short name for the item can be given here, if wanted. It is inherited as a common feature from the type tElementWithIDAndName.
  • description: In addition to a short name a more detailed description can be given here. This shall allow a short overview or hints to the contents of this dat set. It is inherited as a common feature from the type tElementWithIDAndName.
  • maximumCurrentCharging: The maximum current in Ampere while charging the energy storage.
  • maximumCurrentDischarging: The maximum current in Ampere while discharging the energy storage.
  • maximumPowerCharging: The maximum power in Watt while charging the energy storage.
  • maximumPowerDischarging: The maximum power in Watt while discharging the energy storage.
  • maximumChargingEnergy: The maximum energy in kWh charging to the energy storage. The unit 'kWh' was selected here in favour of 'Ws' due to the value range expected for such trainborne energy storage systems.
  • chargingEfficiency: The efficiency as value between 0 and 1 while charging the energy storage.
  • dischargingEfficiency: The efficiency as value between 0 and 1 while discharging the energy storage.
  • meanStorageEfficiency: The mean efficiency as value between 0 and 1 of the energy storage.

Syntactic Constraints / Syntaktische Beschränkungen

The element <energyStorage> with its attributes is optional. However, when used only the attributes id, maximumCurrentCharging, maximumCurrentDischarging, maximumPowerCharging, maximumPowerDischarging and maximumChargingEnergy are mandatory.

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

The efficiency of the energy storage device can be given in three levels of detail: mean value, value per charging/discharging and detailed curves. The user application has to ensure the consistency, if more than one variant is used.

Open issues / Offene Punkte/Pendenzen

Not yet described. / Noch nicht beschrieben.