IS:trainProtectionElementGroupRef: Difference between revisions

From railML 2 Wiki
Jump to navigation Jump to search
[checked revision][checked revision]
 
(Switched redirect direction for some signal children)
Tag: Removed redirect
Line 1: Line 1:
#redirect[[IS:trainProtectionElementGroupRef signal]]
 
== Scheme description / {{Deu|Schemenbeschreibung}} / {{Fra|Description du schéma}} ==
=== Position of IS:trainProtectionElementGroupRef in the XML-Tree / {{Deu|Position von IS:trainProtectionElementGroupRef im XML-Baum}} / {{Fra|position de IS:trainProtectionElementGroupRef dans l’aborescence XML}} ===
 
* Parent: {{IS:Tag|signal}}
 
* Children: ''None''
 
=== Semantics / {{Deu|Bedeutung}} / {{Fra|Sémantique}} ===
 
Sub-element for a reference to a trainProtectionElementGroup, which is connected to the signal's aspect
 
=== Inherited attributes from other data types  / {{Deu|Abgeleitete Attribute von anderen Datentypen}} / {{Fra|Attributs hérités d’autres types données}} ===
 
''None''
 
=== Specific Attributes of IS:trainProtectionElementGroupRef / {{Deu|Spezielle Attribute von IS:trainProtectionElementGroupRef}} / {{Fra|Attributs spécifiques de IS:trainProtectionElementGroupRef}} ===
 
*{{attr|ref}}: reference is required because it's the purpose of the element
 
=== Constraints / {{Deu|Beschränkungen}} / {{Fra|Contraintes}} ===
 
*{{attr|ref}}: tGenericRef
 
== Best practice & Examples / {{Deu|Empfohlene Anwendung & Beispiele}} / {{Fra|Bonnes pratiques & exemples}} ==
 
The following example (taken from SimpleExample) shows how a signal may reference a connected train protection element. The main signal "69A" is a combined signal that works as home signal for the station referenced by the ID "ocp01". This signal references a train protection element group:
 
<syntaxhighlight lang="xml">
<signal id="tr03_si07" pos="3800" absPos="4300" dir="up"
        name="69A" xml:lang="de"
        function="home" type="combined" ocpStationRef="ocp01">
  <trainProtectionElementGroupRef ref="tr03_tpeg01"/>
</signal>
</syntaxhighlight>
 
The referenced train protection element group contains one Indusi magnet, which is positioned at the same track location like the signal:
 
<syntaxhighlight lang="xml">
<trainProtectionElements>
  <trainProtectionElement id="tr03_tpe01" pos="3800" absPos="4300" dir="up"
                          medium="magnetic" trainProtectionSystem="Indusi"/>
  <trainProtectionElementGroup id="tr03_tpeg01">
    <trainProtectionElementRef ref="tr03_tpe01"/>
  </trainProtectionElementGroup>
</trainProtectionElements>
</syntaxhighlight>
 
== Notes / {{Deu|Anmerkungen}} / {{Fra|Notes}} ==
 
''Not yet described. / {{Deu|Noch nicht beschrieben.}} / {{Fra|Pas encore décrit.}}''
<!--
=== Example / {{Deu|Beispiel}} / {{Fra|Exemple}} ===
-->
''Not yet described. / {{Deu|Noch nicht beschrieben.}} / {{Fra|Pas encore décrit.}}''
 
== Open issues / {{Deu|Offene Punkte/Pedenzen}} / {{Fra|Questions ouvertes}} ==
 
''Not yet described. / {{Deu|Noch nicht beschrieben.}} / {{Fra|Pas encore décrit.}}''
 
[[Category:{{
#switch: {{#explode:{{FULLPAGENAME}}|:}}
|CO = Common_Elements
|IS = Infrastructure_Elements
|RS = Rollingstock_Elements
|TT = Timetable_Elements
|Vorlage = Element_Template
|FIXME
}}|{{#explode:{{FULLPAGENAME}}|:|-1}}]]

Revision as of 23:25, 2 July 2021

Scheme description / Schemenbeschreibung /

Position of IS:trainProtectionElementGroupRef in the XML-Tree / Position von IS:trainProtectionElementGroupRef im XML-Baum /

  • Children: None

Semantics / Bedeutung /

Sub-element for a reference to a trainProtectionElementGroup, which is connected to the signal's aspect

Inherited attributes from other data types / Abgeleitete Attribute von anderen Datentypen /

None

Specific Attributes of IS:trainProtectionElementGroupRef / Spezielle Attribute von IS:trainProtectionElementGroupRef /

  • ref: reference is required because it's the purpose of the element

Constraints / Beschränkungen /

  • ref: tGenericRef

Best practice & Examples / Empfohlene Anwendung & Beispiele /

The following example (taken from SimpleExample) shows how a signal may reference a connected train protection element. The main signal "69A" is a combined signal that works as home signal for the station referenced by the ID "ocp01". This signal references a train protection element group:

<signal id="tr03_si07" pos="3800" absPos="4300" dir="up"
        name="69A" xml:lang="de"
        function="home" type="combined" ocpStationRef="ocp01">
  <trainProtectionElementGroupRef ref="tr03_tpeg01"/>
</signal>

The referenced train protection element group contains one Indusi magnet, which is positioned at the same track location like the signal:

<trainProtectionElements>
  <trainProtectionElement id="tr03_tpe01" pos="3800" absPos="4300" dir="up" 
                          medium="magnetic" trainProtectionSystem="Indusi"/>
  <trainProtectionElementGroup id="tr03_tpeg01">
    <trainProtectionElementRef ref="tr03_tpe01"/>
  </trainProtectionElementGroup>
</trainProtectionElements>

Notes / Anmerkungen /

Not yet described. / Noch nicht beschrieben. / Not yet described. / Noch nicht beschrieben. /

Open issues / Offene Punkte/Pedenzen /

Not yet described. / Noch nicht beschrieben. /