Element winding

Description

The element winding contains the nominal values for each transformer winding.

Das Element winding enthält die Bemessungsdaten für die einzelnen Wicklungen des Haupttransformators.

parent

transformer

children

none

attributes

assemblyName
This is the type of transformer winding as descriptive name.
nomVoltage
This is the nominal voltage of transformer winding at primary side in Volts.
nomCurrent
This is the nominal current of transformer winding at primary side in Ampere.
transformationRatio
This is the transformation ratio of the transformer winding according to the relation of primary/secondary voltage.
primaryResistance
This is the resistance of primary winding of one transformer in Ohms.
secondaryResistance
This is the resistance of secondary winding of one transformer in Ohms transformed to primary side.
primaryLeakageInductance
This is the leakage inductance of primary winding of one transformer in Henry.
secondaryLeakageInductance
This is the leakage inductance of secondary winding of one transformer in Henry transformed to primary side.


Back to elements