RS:winding

From railML 2 Wiki
Revision as of 10:01, 12 December 2012 by RailML Coord Rollingstock (talk | contribs) (Constrains updated)
Jump to navigation Jump to search


winding
 


Scheme description / Schemenbeschreibung

Position of winding in the XML-Tree / Position von winding im XML-Baum

  • Parent: <transformer>
  • Children: Not yet described. / Noch nicht beschrieben.

Multiplicity / Anzahl

[1..1]

Semantics / Bedeutung

The element <winding> contains the nominal values for each transformer winding.

Das Element <winding> enthält die Bemessungsdaten für die einzelnen Wicklungen des Haupttransformators.

Attributes of winding / Attribute von winding

  • assemblyName: This is the type of transformer winding as descriptive name.
  • nominalVoltage: This is the nominal voltage of transformer winding at primary side in Volts.
  • nominalCurrent: This is the nominal current of transformer winding at primary side in Ampere.
  • transformationRatio: This is the transformation ratio of the transformer winding according to the relation of primary/secondary voltage.
  • primaryResistance: This is the resistance of primary winding of one transformer in Ohms.
  • secondaryResistance: This is the resistance of secondary winding of one transformer in Ohms transformed to primary side.
  • primaryLeakageInductance: This is the leakage inductance of primary winding of one transformer in Henry.
  • secondaryLeakageInductance: This is the leakage inductance of secondary winding of one transformer in Henry transformed to primary side.

Syntactic Constraints / Syntaktische Beschränkungen

  • nominalVoltage xs:decimal, 1 fraction digit, voltage value measured in Volt, optional
  • nominalCurrent xs:decimal, 1 fraction digit, current value measured in Ampere, optional
  • primaryResistance xs:decimal, 3 fraction digit, electrical resistance value measured in Ohms, optional
  • secondaryResistance xs:decimal, 3 fraction digit, electrical resistance value measured in Ohms, optional
  • primaryLeakageInductance xs:decimal, 6 fraction digit, electrical inductance value measured in Henry, optional
  • secondaryLeakageInductance xs:decimal, 6 fraction digit, electrical inductance value measured in Henry, optional

The element <winding> is optional and can occur several times.

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

Not yet described. / Noch nicht beschrieben.

Open issues / Offene Punkte/Pendenzen

Not yet described. / Noch nicht beschrieben.