== Element '''cosphi''' ==
{{elementDocu|
=== Description ===
elementName = phi
The element '''cosphi''' contains the ratio of the effective power versus the apparent power as curve for the entire propulsion system.


Das Element '''cosphi''' beinhaltet die Beschreibung des Verlaufes des Phasenwinkels am Stromabnehmer des Fahrzeuges über die Leistung. Die Steuerstrategie des 4-Quadrantensteller kann diesen Verlauf entscheidend beeinflussen.
|semantics =
The element {{RS:Tag|phi}} contains the phase angle of the effective power versus the apparent power as curve for the entire propulsion system. The control strategy of the 4-quadrant chopper can influence this value effectively.


=== parent ===
{{deu|Das Element {{RS:Tag|phi}} beinhaltet die Beschreibung des Verlaufes des Phasenwinkels am Stromabnehmer des Fahrzeuges über die Leistung. Die Steuerstrategie des 4-Quadrantensteller kann diesen Verlauf entscheidend beeinflussen.}}
:[[RS:fourQuadrantChopper|fourQuadrantChopper]]


=== children ===
|parent =
:[[RS:manufacturer|manufacturer]]
{{RS:Doc|fourQuadrantChopper}}
:[[RS:operator|operator]]


=== attributes ===
|childs =
:none
{{IntroSegmentTable}}, [[RS:mathml|mml:math]]
|minocc=0
|constraints =
The phase shift value of power shall between -180 and +180 degrees.


 
|backHome = RS:elements
Back to [[RS:elements|elements]]
}}

Latest revision as of 17:35, 2 September 2020


phi
 


Scheme description / Schemenbeschreibung

Position of phi in the XML-Tree / Position von phi im XML-Baum

Multiplicity / Anzahl

[0..1]

Semantics / Bedeutung

The element <phi> contains the phase angle of the effective power versus the apparent power as curve for the entire propulsion system. The control strategy of the 4-quadrant chopper can influence this value effectively.

Das Element <phi> beinhaltet die Beschreibung des Verlaufes des Phasenwinkels am Stromabnehmer des Fahrzeuges über die Leistung. Die Steuerstrategie des 4-Quadrantensteller kann diesen Verlauf entscheidend beeinflussen.

Attributes of phi / Attribute von phi

Not yet described. / Noch nicht beschrieben.

Syntactic Constraints / Syntaktische Beschränkungen

The phase shift value of power shall between -180 and +180 degrees.

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

Not yet described. / Noch nicht beschrieben.

Open issues / Offene Punkte/Pendenzen