RS:fourQuadrantChopper

From railML 2 Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.


fourQuadrantChopper
 


Scheme description / Schemenbeschreibung

Position of fourQuadrantChopper in the XML-Tree / Position von fourQuadrantChopper im XML-Baum

Multiplicity / Anzahl

[0..1]

Semantics / Bedeutung

The element <fourQuadrantChopper> contains all data about the 4-quadrant chopper conditioning the supply energy for the traction purpose.

Das Element <fourQuadrantChopper> beinhaltet alle Angaben zum 4-Quadrantensteller eines Triebfahrzeugs. Dieser vollgesteuerte Umrichter auf der Netzeingangsseite eines Triebfahrzeuges mit Drehstromantriebstechnik dient der Anpassung der bezogenen bzw. abgegebenen Energie zwischen Bahnnetz und Fahrzeug. Er erhielt seinen Namen von der Arbeitsweise den Phasenwinkel zwischen Strom und Spannung durch alle vier Quadranten des komplexen Koordinatensystems steuern zu können. Dies wird beim Einsatz unter Wechselstromsystemen genutzt. Unter Gleichstromsystemen kommt höchstens ein Eingangsstromsteller (Chopper) zum Einsatz, dessen Eigenschaften aber ebenso über dieses Element abgebildet werden können.

Attributes of fourQuadrantChopper / Attribute von fourQuadrantChopper

  • count: This is the number of fourQuadrantChoppers of the same type installed on the vehicle. The use of different types on the same vehicle is not supported.
    The number is considered for calculation of totals of efficiency.
  • meanPhi: This is the mean value of phase shift between voltage and current for operation. This value shall be used, if no more details are needed.
  • meanPhiRegeneration: This is the mean value of phase shift between voltage and current during regeneration. This value shall be used, if no more details are needed but the phase angle differs to normal driving mode.
  • meanEfficiency: This is the mean value of efficiency for operation of the inverter. This value shall be used, if no more details are needed.

Syntactic Constraints / Syntaktische Beschränkungen

  • meanPhi xs:decimal, 6 digits and 3 fraction digit within the range of -180 and +180, angle value measured in degree, optional
  • meanPhiRegeneration xs:decimal, 6 digits and 3 fraction digit within the range of -180 and +180, angle value measured in degree, optional
  • meanEfficiency xs:decimal, range between 0 and 1 (inclusive borders), maximum 6 fraction digits, optional

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

In case of different phase angles in driving and regeneration mode the mean values can be given using the related attributes. In case of more details are required the difference can be defined using the third dimension 'z' of the valueTable.

Open issues / Offene Punkte/Pendenzen

Not yet described. / Noch nicht beschrieben.