RS:energyStorage

From railML 2 Wiki
Revision as of 00:57, 15 September 2020 by RailML Coord Common (talk | contribs) (efficiency link)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search


energyStorage
 


Schema description / Schemabeschreibung

Position of energyStorage in the XML-Tree / Position von energyStorage im XML-Baum

Multiplicity / Anzahl

[0..∞]

Semantics / Bedeutung

The element <energyStorage> is the container for all data of energy storage device on the vehicle. The main focus is on the electrical characteristics.

Das Element <energyStorage> stellt den Container für alle Daten bezüglich eines Energiespeichers auf dem Fahrzeug zur Verfügung. Dabei liegt das Hauptaugenmerk auf den elektrischen Eigenschaften.

Attributes of energyStorage / Attribute von energyStorage

  • maximumCurrentDischarging: The maximum current in Ampere while discharging the energy storage.
  • maximumPowerCharging: The maximum power in Watt while charging the energy storage.
  • maximumPowerDischarging: The maximum power in Watt while discharging the energy storage.
  • maximumChargingEnergy: The maximum energy in kWh charging to the energy storage. The unit 'kWh' was selected here in favour of 'Ws' due to the value range expected for such trainborne energy storage systems.
  • chargingEfficiency: The efficiency as value between 0 and 1 while charging the energy storage.
  • dischargingEfficiency: The efficiency as value between 0 and 1 while discharging the energy storage.
  • meanStorageEfficiency: The mean efficiency as value between 0 and 1 of the energy storage.

Syntactic Constraints / Syntaktische Beschränkungen

  • id: xs:ID, required
    a string, starting with a letter (a..zA..Z) or an underscore (_),
    followed by a non-colonized and non-spaced string consisting of letters, digits, points (.), dashes (-) or underscores (_)
  • code: xs:string, optional
  • name: xs:string, optional
  • description: xs:string, optional
  • xml:lang: xs:language, language identification, optional
  • maximumCurrentCharging xs:decimal, 1 fraction digit, current value measured in Ampere, mandatory
  • maximumCurrentDischarging xs:decimal, 1 fraction digit, current value measured in Ampere, mandatory
  • maximumPowerCharging xs:decimal, 0 fraction digits, power value measured in Watt, mandatory
  • maximumPowerDischarging xs:decimal, 0 fraction digits, power value measured in Watt, mandatory
  • maximumChargingEnergy xs:decimal, 3 fraction digits, energy value measured in kWh, mandatory
  • chargingEfficiency xs:decimal, range between 0 and 1 (inclusive borders), maximum 6 fraction digits, optional
  • dischargingEfficiency xs:decimal, range between 0 and 1 (inclusive borders), maximum 6 fraction digits, optional
  • meanStorageEfficiency xs:decimal, range between 0 and 1 (inclusive borders), maximum 6 fraction digits, optional

The element <energyStorage> itself is optional.

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

The efficiency of the energy storage device can be given in three levels of detail: mean value, value per charging/discharging and detailed curves. The user application has to ensure the consistency, if more than one variant is used.

Open issues / Offene Punkte/Pendenzen

Not yet described. / Noch nicht beschrieben.