RS:dedicatedSupplySystem auxiliarySupply

From railML 2 Wiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.


dedicatedSupplySystem
 


Scheme description / Schemenbeschreibung

Position of dedicatedSupplySystem in the XML-Tree / Position von dedicatedSupplySystem im XML-Baum

  • Parent: auxiliarySupply
  • Children: Not yet described. / Noch nicht beschrieben.

Multiplicity / Anzahl

[0..∞]

Semantics / Bedeutung

(after version 2.0)

The element <dedicatedSupplySystem> in context of auxiliarySupply is used for the capabilities per possible auxiliary supply system.

Das Element <dedicatedSupplySystem> wird im Kontext von auxiliarySupply zur Beschreibung der Leistungsmerkmale für jedes mögliche Hilfsbetriebespeisesystem verwendet.

Attributes of dedicatedSupplySystem / Attribute von dedicatedSupplySystem

  • voltage: The nominal voltage in Volt for the supply system.
  • frequency: The nominal frequency in Hertz for the supply system. '0' means DC system.
  • maxPower: The maximum power, which can be drawn with this supply system.

Syntactic Constraints / Syntaktische Beschränkungen

The element is optional and can occur several times. However, if used a value for maxPower is required.

Best practice & Examples / Empfohlene Anwendung & Beispiele

Not yet described. / Noch nicht beschrieben.

Notes / Anmerkungen

For European railways there are four typical systems:

  • 1000 V 16.7 Hz
  • 1000 V 50 Hz
  • 1500 V DC
  • 3000 V DC

Open issues / Offene Punkte/Pendenzen

Not yet described. / Noch nicht beschrieben.