IS:trainProtectionElementGroupRef signal: Difference between revisions
Jump to navigation
Jump to search
[checked revision] | [checked revision] |
(subst) |
(→Best practice & Examples / {{Deu|Empfohlene Anwendung & Beispiele}} / {{Fra|Bonnes pratiques & exemples}}: best practice example for signal reference to train protection element group) |
||
Line 25: | Line 25: | ||
== Best practice & Examples / {{Deu|Empfohlene Anwendung & Beispiele}} / {{Fra|Bonnes pratiques & exemples}} == | == Best practice & Examples / {{Deu|Empfohlene Anwendung & Beispiele}} / {{Fra|Bonnes pratiques & exemples}} == | ||
The following example (taken from SimpleExample) shows how a signal may reference a connected train protection element. The main signal "69A" is a combined signal that works as home signal for the station referenced by the ID "ocp01". This signal references a train protection element group: | |||
< | |||
< | <syntaxhighlight lang="xml"> | ||
== | <signal id="tr03_si07" pos="3800" absPos="4300" dir="up" | ||
name="69A" xml:lang="de" | |||
function="home" type="combined" ocpStationRef="ocp01"> | |||
<trainProtectionElementGroupRef ref="tr03_tpeg01"/> | |||
</signal> | |||
</syntaxhighlight> | |||
The referenced train protection element group contains one Indusi magnet, which is positioned at the same track location like the signal: | |||
<syntaxhighlight lang="xml"> | |||
<trainProtectionElements> | |||
<trainProtectionElement id="tr03_tpe01" pos="3800" absPos="4300" dir="up" | |||
medium="magnetic" trainProtectionSystem="Indusi"/> | |||
<trainProtectionElementGroup id="tr03_tpeg01"> | |||
<trainProtectionElementRef ref="tr03_tpe01"/> | |||
</trainProtectionElementGroup> | |||
</trainProtectionElements> | |||
</syntaxhighlight> | |||
== Notes / {{Deu|Anmerkungen}} / {{Fra|Notes}} == | == Notes / {{Deu|Anmerkungen}} / {{Fra|Notes}} == | ||
Revision as of 18:03, 5 April 2017
Scheme description / Schemenbeschreibung /
Position of IS:trainProtectionElementGroupRef signal in the XML-Tree / Position von IS:trainProtectionElementGroupRef signal im XML-Baum /
- Parent: <signal>
- Children: None
Semantics / Bedeutung /
Sub-element for a reference to a trainProtectionElementGroup, which is connected to the signal's aspect
Inherited attributes from other data types / Abgeleitete Attribute von anderen Datentypen /
None
Specific Attributes of IS:trainProtectionElementGroupRef signal / Spezielle Attribute von IS:trainProtectionElementGroupRef signal /
- ref: reference is required because it's the purpose of the element
Constraints / Beschränkungen /
- ref: tGenericRef
Best practice & Examples / Empfohlene Anwendung & Beispiele /
The following example (taken from SimpleExample) shows how a signal may reference a connected train protection element. The main signal "69A" is a combined signal that works as home signal for the station referenced by the ID "ocp01". This signal references a train protection element group:
<signal id="tr03_si07" pos="3800" absPos="4300" dir="up" name="69A" xml:lang="de" function="home" type="combined" ocpStationRef="ocp01"> <trainProtectionElementGroupRef ref="tr03_tpeg01"/> </signal>
The referenced train protection element group contains one Indusi magnet, which is positioned at the same track location like the signal:
<trainProtectionElements> <trainProtectionElement id="tr03_tpe01" pos="3800" absPos="4300" dir="up" medium="magnetic" trainProtectionSystem="Indusi"/> <trainProtectionElementGroup id="tr03_tpeg01"> <trainProtectionElementRef ref="tr03_tpe01"/> </trainProtectionElementGroup> </trainProtectionElements>
Notes / Anmerkungen /
Not yet described. / Noch nicht beschrieben. / Not yet described. / Noch nicht beschrieben. /
Open issues / Offene Punkte/Pedenzen /
Not yet described. / Noch nicht beschrieben. /